6680A-TAA6681A-TAA6684A-TAA• Low output ripple and noise• Selectable compensation for inductive loads

• Analog control of output voltage and current

• Fan-speed control to minimize acoustic noise

• Built-in measurements and

advanced programmable features• Protection features to ensure DUT safety

Agilent 6680A Series Single-Output, 5000 W DC Power Supplies, GPIB

Data Sheet

Reliable DC power for manufacturing test and long-term burn-in

This series of 5000 watt DC power The output voltage and current supplies has the exceptional, proven can also be controlled with analog reliability that test system engineers signals. This is helpful for certain look for. It also has the features types of noisy environments, and needed for easy test system also immediate reactions to process integration.

changes.

Programming of the DC output and The 6680A series has extremely low the extensive protection features can ripple and noise for a 5000 watt DC be done either from the front panel power supply. This helps the built-in or using industry standard SCPI com-measurement system make extremely mands via the GPIB. Using the serial accurate current and voltage link, up to 16 power supplies can be measurements.

connected through one GPIB address. Test system integration can be further Selectable compensation is provided simplified by using the VXIplug&play for problem-free powering of inductive drivers.

loads.

Specifi cations

Specifications(at 0 ° to 55 °C unless otherwise specified)Number of outputs GPIB Output ratingsVoltage Current (40 °C then derate linearly 1%/°C from 40 °C to 55 °C)Programming accuracy at 25 °C ± 5 °CVoltage Current 0.04% +0.1% +5 mV 450 mA 8 mV 300 mA 21 mV 125 mA 32 mV 85 mA 40 mV65 mA5 mV450 mA0 to 5 V 0 to 875 A 0 to 8 V 0 to 580 A 0 to 21 V 0 to 240 A 0 to 32 V 0 to 160 A 0 to 40 V0 to 128 A0 to 3.3 V0 to 1000 A6680A6681A6682A6683A6684ASpecial order option6680A-J041 1 1 1 1Yes Yes Yes Yes Yes1YesRipple and noise constant voltage mode from 20 Hz to 20 MHzVoltage Readback accuracy at 25 °C ± 5 °C(percent of reading plus fi xed)Voltage CurrentLoad and line regulationVoltage Current Transient response time 0.002% +0.005% +0.19 mV65 mA 0.3 mV40 mA 0.65 mV 17 mA 1.1 mV 12 mA 1.5 mV9 mA0.19 mV77 mA0.05% +0.1% +7.5 mV 600 mA12 mV 400 mA32 mV 165 mA 48 mV 110 mA 60 mV90 mA 7.5 mV600 mArms 1.5 mV 1.5 mV10 mV 1.5 mV10 mV 1.0 mV 10 mV 1.0 mV10 mV 3.4 mV15 mVpeak-to-peak 10 mV Less than 900 μs for the output voltage to recover to within 150 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply6680A-J04Supplemental characteristics(Non-warranted characteristics determined by design and useful in applying the product)Ripple and noise constant current mode from 20 Hz to 20 MHzCurrent Average programming resolutionVoltage Current OVPOutput voltage programming response time*(excluding command processing time)Output common-mode noise current(to signal-ground binding post) rms rms 6680A6681A6682A6683A6684ASpecial order option290 mA1.35 mV235 mA30 mV190 mA2.15 mV155 mA45 mV40 mA5.7 mV mA120 mV28 mA 8.6 mV43 mA180 mV23 mA10.8 mV34 mA225 mV—12 mV260 mV25 mV9 ms1.5 mA 12 ms1.5 mA10 mA 45 ms3 mA20 mA 60 ms3 mA 20 mA60 ms3 mA20 mA9 ms2.0 mA12.5 mApeak-to-peak 10 mA * Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current.2

Supplemental characteristics for all model numbers

DC floating voltage: Output terminals can be floated up to ± 60 VDC from chassis ground

Remote sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load.

Command processing time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for power supplies connected directly to the GPIB.

Modulation: (Analog programming of output voltage and current):

Input signal: 0 to –5 V for voltage, 0 to +5 V for current

Input impedance: 30 kΩ or greaterAC input (47 to 63 Hz):

180 to 235 VAC (line-to-line, 3 phase), 27.7 A rms maximum worst case, 21.4 A rms nominal; 360 to 440 VAC, 14.3 A rms maximum worst case, 10.7 A rms nominal (maximum line current includes 5% unbalanced phase voltage condition.) Output voltage derated 5% at 50 Hz and below 200 VACInput power: 7350 VA and 6000 W maximum; 160 W at no load

GPIB interface capabilities:

SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI command set.Software driver: • IVI-COM • VXIplug&play

Size:

425.5 mm W x 221.5 mm H x 674.7 mm D (16.75 in x 8.75 in x 25.56 in)Weight: Net, 51.3 kg (113 lbs); shipping, 63.6 kg (140 lbs)Warranty: One year

Agilent models: 6680A, 6681A, 6682A, 6683A, 6684A

Top

12.7 mm0.5\"Buss Bar Detail3/8\" Diameter (6)425.5 mm16.75\"–+3 3/4\" 28.6 mm1.13\"30.2 mm1.19\"65.1 mm2.56\"27.8 mm1.09\"674.7 mm26.56\"667.3 mm26.27\"574 mm22.6\"221.5 mm8.75\"Rear9.5 mm0.38\"Output Buss BarsSide12.7 mm0.5\"3

Ordering information

The 6680A power supplies come with full documentation on CD-ROM. The CD-ROM includes user’s guide, programming guide, service manual, quick start guide, and application notes.Opt 208 180 to 235 VAC, 3 phase, 47 to 63 Hz

Opt 400 360 to 440 VAC, 3 phase, 47 to 63 Hz

Opt 602 Two bus bar spacers for paralleling power supplies (p/n 5060-3514)

Opt 0L1 Printed user’s and programming guides

Opt 0B3 Printed service manualAccessories

1CM028A* Rack mount flange kit 88.1 mm H (3U) and 132.6 mm H (2U) – 4 brackets (5U total)

1CP014A* Double rack mount flange and handle kit 88.1 mm H (2U) and 132.6 mm H (3U)

E3663AC Support rails for Agilent rack cabinets

p/n 5080-2148 Serial link cable 2 m (6.6 ft.)

p/n 5060-3513 Three 30 A replace-ment fuses for 180 to 235 VAC linep/n 5060-3512 Three 16 A replace-ment fuses for 360 to 440 VAC line

Application notes

6671A/72A/81A/82A/90A System DC Power Supplies Product Overview 5988-3050EN

Agilent DC Power Supplies for Base Station Testing, 5988-2386EN10 Practical Tips You Need to Know About Your Power Products, 5965-8239E

* Support rails required

www.agilent.com

www.agilent.com/find/6680

For more information on Agilent

Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:

www.agilent.com/fi nd/contactus

Agilent Advantage Services is committed

to your success throughout your equip-Americasment’s lifetime. To keep you competitive, Canada (877) 4 4414we continually invest in tools and

Brazil (11) 4197 3600processes that speed up calibration and Mexico

01800 50 800repair and reduce your cost of ownership. United States

(800) 829 4444

You can also use Infoline Web Services to manage equipment and services more Asia Pacifi c

effectively. By sharing our measurement Australia 1 800 629 485and service expertise, we help you create China 800 810 01the products that change our world.

800 938 693India 1 800 112 929www.agilent.com/find/advantageservices

Japan 0120 (421) 345Korea 080 769 0800Malaysia 1 800 888 848Singapore 180****8100DEKRAISO 9001:2008

CertifiedTaiwan 0800 047 866Quality Management SysQuality Management System

Other AP Countries (65) 375 8100www.agilent.com/quality

Europe & Middle EastBelgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15Agilent Email Updates

Finland 358 (0) 10 855 2100www.agilent.com/find/emailupdates

France 0825 010 700*

*0.125 €/minute

Get the latest information on the Germany 49 (0) 7031 4 6333products and applications you select.

Ireland 10 924 204

Israel 972-3-9288-504/4Agilent Channel Partners

Italy

39 02 92 60 8484www.agilent.com/find/channelpartnersNetherlands 31 (0) 20 7 2111Get the best of both worlds: Agilent’s Spain 34 (91) 631 3300measurement expertise and product Sweden

0200-88 22 55

United Kingdom 44 (0) 118 927 6201

breadth, combined with channel partner convenience.

For other unlisted countries: www.agilent.com/fi nd/contactus

Revised: January 6, 2012

Product specifications and descriptions in this document subject to change without notice.

© Agilent Technologies, Inc. 2012Published in USA, March 14, 20125990-9307EN

6680A-TAA6681A-TAA6684A-TAA

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- efsc.cn 版权所有 赣ICP备2024042792号-1

违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务