山东电力集团公司 2011年10-35千伏等 主要设备材料第五批集中招标
招标文件
东营供电公司 新建工程(201131市)
镀锌钢绞线 技术规范书
第三册 (技术专用部分)
招标人:国家电网公司
招标代理机构:山东鲁能三公招标有限公司
二O一一年八月
目 次
1 标准技术参数 ·············································································································· 4
1.1 1×7-7.8-1270-B(GJ-35)标准技术参数 ············································································· 4 1.4 1×7-11.4-1270-B(GJ-80)标准技术参数 ············································································ 4 2 项目需求部分 ·············································································································· 5 2.1 货物需求及供货范围一览表 ·························································································· 5 2.2 图纸资料提交单位 ···································································································· 5 2.3 工程概况 ··············································································································· 5 2.4 使用条件 ··············································································································· 6 2.5 项目单位技术差异 ···································································································· 6 3 投标人响应部分 ··········································································································· 7
1 标准技术参数
投标人应仔细阅读表23货物需求及供货范围一览表,并认真逐项填写所招标规格的镀锌钢绞线技术参数响应表中“投标人保证值”,不能以“响应”两字代替,不允许改动招标人要求值。如有偏差,请填写技术偏差表。
1.1 1×7-7.8-1270-B(GJ-35)标准技术参数
1.1-1 1×7-7.8-1270-B(GJ-35)镀锌钢绞线技术参数响应表
项 目 制造厂(商) 原产地 产品型号规格 外观及表面质量 结构 计算截面积 外径 单位长度重量 绞线破断拉力 弹性模量 线膨胀系数 内层 邻外层 节径比 外层 对于有多层的绞线 外层 绞向 其他层 每盘绞线净重 每盘绞线毛重 每盘线长 长度允许偏差 负 镀锌钢线不应有任何接头 % 0 (投标人填写) 正 / kg kg m % / / / 2500 0.5 / (投标人填写) (投标人填写) (投标人填写) (投标人填写) / / / 10~14 / 右向 (投标人填写) / (投标人填写) 股数/直径 根/mm mm2 mm kg/100m kN GPa 1/℃ / / 单 位 招 标 人 要 求 值 (投标人填写) (投标人填写) 1×7-7.8-1270-B 绞线表面不应有肉眼可见的缺陷,如明显的压痕、划痕等,并不得有与良好商品不相称的任何缺陷 7/2.60 37.17 7.8 29.51 ≥43.42 185.0 11.5×106 / / (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) / / 投标人保证值 1.1-2 1×7-7.8-1270-B(GJ-35)镀锌钢线技术参数响应表
项 目 制造厂(商) 原产地 单 位 招 标 人 要 求 值 (投标人填写) (投标人填写) 投标人保证值 表2(续)
项 目 外观及表面质量 直径 直径允许偏差 正 负 抗拉强度 伸长率(标距200mm) 扭转(L=100d) 镀锌层质量 缠绕 镀锌层连续性 计算截面积 单位长度质量 单 位 mm mm mm MPa % 次/360º g/m2 / / mm2 kg/km 招 标 人 要 求 值 投标人保证值 镀锌钢线应较光洁,并且不应有与良好的(投标人填写) 商品不相称的所有缺陷 2.60 0.08 0.08 ≥1270 ≥3.0 ≥16 ≥200 (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) 14倍钢线直径紧密缠绕6圈,锌层不得开(投标人填写) 裂或起层到用裸手指能够擦掉的程度 钢线表面应镀上均匀连续的锌层,不得有(投标人填写) 裂纹和漏镀 5.31 41.31 (投标人填写) (投标人填写)
1.4 1×7-11.4-1270-B(GJ-80)标准技术参数
1.4-1 1×7-11.4-1270-B(GJ-80)镀锌钢绞线技术参数响应表
项 目 制造厂(商) 原产地 产品型号规格 外观及表面质量 结构 计算截面积 外径 单位长度重量 绞线破断拉力 弹性模量 线膨胀系数 内层 节径比 邻外层 外层 股数/直径 根/mm mm2 mm kg/100m kN GPa 1/℃ / / / 单 位 招 标 人 要 求 值 (投标人填写) (投标人填写) 1×7-11.4-1270-B 绞线表面不应有肉眼可见的缺陷,如明显的压痕、划痕等,并不得有与良好商品不相(投标人填写) 称的任何缺陷 7/3.80 79.39 11.4 63.04 ≥92.75 185.0 11.5×106 / / 10~14 (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) / / (投标人填写) 投标人保证值 对于有多层的绞线 外层 绞向 其他层 每盘绞线净重 每盘绞线毛重 每盘线长 正 长度允许偏差 负 镀锌钢线不应有任何接头 / / / kg kg m % % / 右向 / / / 2500 0.5 0 / (投标人填写) / (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) 1.4-2 1×7-11.4-1270-B(GJ-80)镀锌钢线技术参数响应表
项 目 制造厂(商) 原产地 外观及表面质量 直径 正 直径允许偏差 负 抗拉强度 伸长率(标距200mm) 扭转(L=100d) 镀锌层质量 缠绕 镀锌层连续性 计算截面积 单位长度质量 mm MPa % 次/360° g/m2 / / mm2 kg/km 0.10 ≥1270 ≥4.0 ≥14 ≥250 (投标人填写) (投标人填写) (投标人填写) (投标人填写) (投标人填写) mm mm 单 位 招 标 人 要 求 值 (投标人填写) (投标人填写) 镀锌钢线应较光洁,并且不应有与良好的(投标人填写) 商品不相称的所有缺陷 3.80 0.10 (投标人填写) (投标人填写) 投标人保证值 14倍钢线直径紧密缠绕6圈,锌层不得开(投标人填写) 裂或起层到用裸手指能够擦掉的程度 钢线表面应镀上均匀连续的锌层,不得有(投标人填写) 裂纹和漏镀 11.34 88.23 (投标人填写) (投标人填写)
2 项目需求部分
2.1 货物需求及供货范围一览表
货物需求及供货范围一览表见表。
货物需求一览表
项目单位要求 序号 项目名称 物料描述 包号 单位 千米 千米 千米 千米 千米 千米 投标人响应 数量 物料型号 主要参数 单位 数量 采购申请 行号 1 2 3 4 5 6 东营10kV八吕线延伸工程 东营10kV八吕线延伸工程 1×7-11.4-1270-B(GJ-80) 1×7-7.8-1270-B(GJ-35) 3100025216 3100025216 40 30 0.7 1.6 注 1. 项目单位在表中“工程名称”栏填写使用所采购镀锌钢绞线的工程项目名称。
2. 在“项目单位要求”部分填写所采购镀锌钢绞线的“数量”和“技术参数”;在其他规格镀锌钢绞线的相应部分填写“/”。
2.2 图纸资料提交单位
卖方向买方提供的图纸、说明书、试验报告等技术资料的交付时间、数量及接收单位见表24。
表24 技术资料交付明细
序号 1 1.1 1.2 1.3 1.4 2 2.1 2.2 项 目 图纸类 产品结构图 线盘图 线盘包装图 线盘起吊尺寸图 参数表及说明书 单线的技术参数响应表及说明书 绞线的技术参数响应表及说明书 提交份数 6 6 6 6 6 6 山东电力集团公司东营供电公司 山东电力集团公司东营供电公司 交货前 接收单位 交付时间 表24(续)
序号 3 3.1 项 目 试验报告 出厂试验报告 提交份数 6 接收单位 山东电力集团公司东营供电公司 交付时间 3.2 根据导、地线的不同要求提供相应的型式试验报告 6
2.3 工程概况
本工程项目单位: 山东电力集团公司东营供电公司 。 本工程设计单位: 东营方大电力规划设计有限公司
表25 工 程 概 况
工程名称 10kV八吕线延伸工程 线路长度(km) 9.2km 最大档距(m) 50m 安装地点 东营市河口区
2.4 使用条件
表26 环 境 条 件
序号 1 2 3 项 目 海拔高度(m) 环境温度(℃) 日照(W/cm2) 内 容 ≤1000m -20℃~+40℃ 0.1w/cm 序号 4 5 项 目 覆冰厚度(mm) 最大风速(m/s) 内 容 10mm 30m/s
2.5 项目单位技术差异
项目单位原则上不能改动通用部分技术条款及专用部分固化的参数,根据工程实际情况,使用条件及相关技术参数如有差异,应逐项在技术差异表中列出。
表27 项目单位技术差异表(项目单位填写)
序号 1 2 3 序号 1 2 3 项 目 项 目 招标人要求值 变更条款页码、款号 项目单位要求值 原表述 投标人保证值 变更后表述 3 投标人响应部分
投标人应逐项响应本技术规范书中的要求,如有与本技术规范书要求不一致的地方,应逐项在投标人技术偏差表中列出,必要时应提供相应的试验报告。
表28 投标人技术偏差表
序号 1 项 目 对应条款编号 技术规范书要求 偏 差 备 注 2 3 4
因篇幅问题不能全部显示,请点此查看更多更全内容
Copyright © 2019- efsc.cn 版权所有 赣ICP备2024042792号-1
违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com
本站由北京市万商天勤律师事务所王兴未律师提供法律服务