不需要打印封面,有专门的封面
旧底图登记号 Mk QTY REVISION SIGN
DESIGN CHECK
底图登记号 VERIFY
APPRO DATE
DATE
5500DWT
CHEMICAL TANKER
TECHNICAL DESIGN
SINGLE LINE DIAGRAM OF
EMERGENCY SWITCHBOARD AREA
NDF566-026-22
m2SHEETS 10
PAGE 1
NINGBO ORIENTAL SHIP DESIGN CO., LTD
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 2
说明:Note: 一、结构及外形Composition and construction 1、组成:由应急发电机屏1屏、负载屏1屏,共2屏组成。外形尺寸为:1400×650×2000mm(含底座)。 Emergency switchboard consists of as follows: One (1) panel of switchboard of generators, 440V/220V feeder panel, Total is two (2) panels. The dimension of configuration: about 1400 (length) ×650 (depth) ×2000 (height) (including underbed). 2、结构: ① 配电板为骨架结构,前后开门式,板后维修。 ESB is to be of upright steel frame structure, door type structure of front. The maintenance space is behind ESB. ② 顶部达到防护等级为IP22的要求,并装有吊装环。 The degree of protection on the top of ESB is IP22, and the hoisting ring must be at the top of ESB. ③ 每屏控制屏设有板前照明。 Light to be provided on front of panel of ESB. ④ 前后均设有绝缘扶手,地上铺设绝缘耐油橡皮垫。 The isolated handrails are in front and rear of ESB, non-slipping and oil-proof non-conducting carpet to be fitted in front and at the rear of the ESB. ⑤ 输入输出接线端应设有永久性标记,要求接线方便,便于维修。 The terminals of wires in and out of ESB are provided everlasting marks, so as to connect and repair easy. 3、铭牌:选用滞燃材料,一般采用白底黑字,应急用途采用白底红字。 Nameplates are made of flame retardant material, White background with black letter for general use, white background with red letter for emergency use. 二、供电的连续性Continuous supply 当主汇流排失电时,在45秒钟之内能自动起动应急发电机,并自动连接于应急配电板,供电给从瘫船状态恢复推进所必需依靠的应急电源及其
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 3
他应急负载。如舵机、应急消防泵、机舱应急风机、应急空压机、机舱集控台、航行信号灯、助航设备、无线电设备、火灾报警、应急照明及其他应急通导设备。 When the main source failure, the emergency generator to be started automatically and connect to ESB automatically less than 45s before supply power successfully, supply power to necessary emergency source and other emergency loads during the period from dead ship condition to the thrusters restored. Such as steering gear, emergency fire pump, emergency air compressor, navigation light, signal lights, navigation equipments, radio equipments etc, in general, when main generators are running, emergency generator isn't running, the loads connected to ESB are fed from MSB through the cable connected MSB and ESB. 三、安全运行Safe operation 1、监测设备Instrument ① 仪表:监测仪表选用F96型船用电表,仪表的表面应在发电机的电压、电流、功率的额定值处划出红色标记,电流互感器和电压互感器的次级绕组应可靠接地。 Meters are marine meters F96 series. At the scale of rated voltage, current, power red scale line must be marked. The secondary coil of transformers of voltage and current are to be grounded firmly. ② 绝缘监测:在应急配电板上设电网绝缘监测仪,可同时对440V电力汇流排及220V照明汇流排的绝缘进行监测和报警。 A set of monitoring instrument of network isolation is to be provided in ESB. It is able to monitor the isolations of both 440V power bus-bar and 220V lighting bus-bar, and then get out an alarm signal. 2、发电机保护Protection of generator 主开关选用NS250L型空气断路器,应急发电机主开关具有过载预报警、过载长延时、短延时时二段保护特性,并具有欠电压脱扣保护装置. Automatic circuit breaker of generators is of NS250, It with two parts over-current protect (overload pre-alarm, overload long time delay tripping, short time delay
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 4
tripping), one part voltage protect (lost voltage tripping). 3、应急发电机与发电机和岸电之间的联锁 应急发电机与发电机、岸电均联锁,当任何一台发电机的主开关合闸即主配电板的主汇流排有电且向应急配电板供电时,应急配电板与主配电板的联络开关可以合闸,它与应急发电机的主开关4MQF联锁,使得4MQF不能合闸,只有当主配电板的主汇流排失电不能向应急配电板供电时,联络开关应能自动立即断开,应急发电机的主开关方可合闸。 The interlock circuit between E/G and D/G, E/G and shore supply power are to be provided. While any one (1) set ACB of generator is on, as well the bus-bar of MSB is electrified and power supply is supplied to ESB, the switch that is connected MSB and ESB may be turned on. Because there is interlock between interconnection switch and 4MQF, so switch 4MQF is not able be turned on. When the bus-bar is lost voltage, and power is not able to be supplied to ESB, interconnection switch is turned off at once, and switch of E/G is able to be turned on. 4、分路开关选用NS系列自动空气断路器,重要负载可选择脱扣器形式,图中标有UVT的为应急配电板与主配电板的失压脱扣,图中标有SHT的为应急发电机室风机,机舱风机遥切分励脱扣。 The feeder switches are NS series auto air breaker. Important loads shall use trip type, UVT means lose voltage trip between MSB and ESB, SHT means emergency shutdown of fans. 5、发电机的空间加热器应与发电机开关联锁,当发电机运行时空间加热器自动断开。 Generator’s space heater shall be interlocked with the circuit breaker. When generator is running, the heater will be shut down automatically. 6、为防止无线电干扰,在AC440V和AC220V回路中均设置滤波电容器。 For against radio interfere, filters in AC440V and AC220V net are to be provided. 7、仪表、开关、指示灯、按钮、操作手柄及熔断器等均应设有标明其用途和操作位置的耐久铭牌,自动开关和熔断器的铭牌均应刻有过载保护整定值。 Everlasting name-plates of instruments, switches, indicate lamps, buttons, handles
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 5
and fuses are to be provided. And on the name-plate of auto-switches and fuses the set value and overload protective value are to be shown. 8、配电板制造厂应根据本图出原理图,并经船检审查认可后制造。 According to this diagram, the detail diagram of MSB is to be submitted to the society for approval by manufacturer, and be made after approval. 四、应急发电机主开关参数:4MQF The parameter of automatic circuit breaker of generator as follows: 型 号 TYPE NS250L+STR22GE+MT+MX+MN 发电机额定电流 RATED CURRENT OF GENERATOR Ie=144A Ir=0.9xIe=0.9x144=129.6A 15s Ir=1.3xIe=1.3x144=187.2A 30s Im=2.5xIe=2.5x144=360A 0.6s 0.7x400V 动作时间 1s SET TIME 1s 过载预报警OVERLOAD PRE ALARM ELECTRONIC TRIPPER 整定电流(Ir) (A) SET CURRENT 整定时间(Tr) (S) SET TIME 过载长延时LONG TIME DELAY TRIPPING WHEN OVERLOAD 整定电流(Ir) (A) SET CURRENT 电子脱扣器 整定时间(Tr) (S) SET TIME 整定电流(Im) (A) 整定时间(Tm) (S) SET TIME 过载短延时TRIPPING WHEN OVERLOAD SHORT TIME DELAY SET CURRENT 欠电压脱扣器整定值 SET VOLTAGE OF LOSS VOLTAGE TRIP
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 6
序 号 NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 代 号 SYMBOL 4MQF 1V 2V 1A 2A KW Hz 1MΩ 2 MΩ 1LW 2LW 3LW 1SB 2SB 3SB 4SB 5SB 1HL 2HL 3HL 4HL 名 称 NAME 主空气断路器 switch of emergency generator 交流电压表 AC voltmeter 交流电压表 AC voltmeter 交流电流表 AC ampere meter 交流电流表 AC ampere meter 功率表 Power meter 频率表 Frequency meter 交流电网绝缘监测仪 insulation monitor 电压表转换开关 Changeover switch of voltmeter 电流表转换开关 Changeover switch of ammeter 发电机空间加热开关 Switch of space heater of E/G 主开关合闸按钮 Turn-on button 主开关分断按钮 Turn-off button 联络开关合闸按钮 Turn-on button 联络开关分闸按钮 Turn-off button 消音按钮 Silencing button 主开关合闸指示灯 Turn-on indication 主开关分断指示灯 Turn-off indication 联络开关合闸指示灯 Turn-on indication 联络开关分闸指示灯 Turn-off indication 型 号 规 格 TYPE AND STANDARD NS250L+STR22GE+MT+MX+MN F96AC-V 0-500V 500/100V F96AC-V 0-300V F96AC-A 0-200A 200/5A F96AC-A 0-75A 75/5A F96-W 0-120KW F96-Hz 55~65Hz F96-MΩ 0-5 MΩ LW95-15 15A 500V LW95-15 15A 500V LW95-15 15A 500V XB2BA31C XB2BA42C XB2BA31C XB2BA42C XB2BA31C XB2BVM3C 220V XB2BVM4C 220V XB2BVM3C 220V XB2BVM4C 220V 数量 QTY. 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 备 注 REMARK 450V处划红线 Red line on 450V 230V处划红线 Red line on 230V 144A处划红线 Red line on 144A 90KW处划红线 Red line on 90kW 绿 Green 红 Red 绿 Green 红 Red 绿 Green 绿 Green 红 Red 绿 Green 红 Red
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 7
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 5HL 6HL 7HL 8HL 9HL 10HL 11HL 1TL 1TV 2TV 1CT VER KA OCR 1-1 1-2 1-3 1-4 1-5 1-6 1-7 主电网投入指示灯 Ind. of MSB supplying 自起动失败报警指示灯 Ind. of self-starter failure 动力网络绝缘低报警指示灯 Ind. of low isolation of power net 照明网络绝缘低报警指示灯 Ind. of low isolation of LT net 空间加热器运行指示灯 Ind. of space heater 应急发电机过载指示灯 Ind. of overload for E/G 低压放电指示灯 Ind. of charging&dis. board 配电屏前照明变压器 Transformer of panel 汇流排电压互感器 Voltage transformer of busbar 发电机电压互感器 Vol. transformer of generator 发电机电流互感器 Current transformer of D/G 发电机电压调整电位器 Potentiometer of E/G volt. adjusting 中间继电器 Auxiliary relay XB2BVM3C 220V XB2BVM4C 220V XB2BVM4C 220V XB2BVM4C 220V XB2BVM6C 220V XB2BVM4C 220V XB2BVM3C 220V LQG-0.5 200A/5A 1 1 1 1 1 1 1 1 2 2 2 1 1 2 1 1 1 1 1 1 1 绿 Green 红 Red 红 Red 红 Red 蓝 Red 红 Red 绿 Green 根据线路需要 On need SHT:ES3 瞬动 INST SHT:ES1 应急变压器热继电器 整定值:23A Thermal relay of emer. transformer Set value:23A 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker NS100N TM 16 16/100 NS100N TM 40 40/100 NS100N TM 16 MX 16/100 NS100N TM 40 40/100 NS100 MA 150/100 NS100N TM 25 25/100 NS100N TM 40 MX 40/100
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 8
42 43 44 45 46 47 48 49 50 51 52 53 55 56 57 58 59 60 61 62 1-8 1-9 1-10 1-11 1-12 1-13 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-11 2-12 2-13 2-14 2-15 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker NS100N TM 25 25/100 NS250 STR22SE MN 160/250 NS100N STR22SE MX 32/100 NS100N STR22SE MX 32/100 NS100N TM 40 40/100 NS100N TM 25 25/100 C65N-C 25/63 C65N-C 25/63 C65N-C 25/63 C65N-C 16/63 C65N-C 16/63 C65N-C 16/63 C65N-C 25/63 C65N-C 25/63 C65N-C 16/63 C65N-C 16/63 C65N-C 25/63 C65N-C 25/63 C65N-C 16/63 C65N-C 25/63 C65N-C 16/63 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 UVT SHT SHT
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 9
63 65 66 67 68 69 2-16 2-17 2-18 2-19 2-20 1KM、2KM 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 自动空气断路器 Automatic circuit breaker 照明接触器 Contactor 电动机构 Motor drive mechanism C65N-C 16/63 C65N-C 25/63 C65N-C 25/63 C65N-C 16/63 C65N-C 25/63 LC1-D6511C 450V+LA1-DN11C MT250 1 1 1 1 1 2 1 联络开关配合使用 Supplied with MCCB
SINGLE LINE DIAGRAM OF EMERGENCY SWITCHBOARD NDF566-026-22 SHEETS:10 PAGE: 10