During mold height slow advance in auto clamp force setup process, the following message is sometimes displayed, thereby auto clamp force setup process stops halfway. In this case, change functional data (C05) of the internal data in the mold height inverter according to the following For where the mold height inverter is mounted, refer to the page after next. 108 ? Mold too thin. (or Mold height does not work in low-speed-step) ? 1. Push [PRG/RESET]. (“F00” is displayed, and program mode comes.) 2. Push [FUNC/DATA]. ( “1” is displayed.) 3. Push [STOP] and [∨] at the same time. (The display changes from “1 “to “0”.) 4. Push [FUNC/DATA].(“F01” is displayed, whereby it becomes possible to change internal data.) 5. Push [∧] [∨] to change functional data. (Cause “C05” to be displayed.) ※ C05: Multistage frequency 1 (Comes the speed during mold height slow advance in auto clamp setup process.) 6. Push [FUNC/DATA] . (Inside data are displayed. Setting on shipping from TOYO: 3.0) 7. Push [∧] [∨] to change data. (The recommended value: 6.0, The maximum value: 10.0) 8. Push [FUNC/DATA] to write data. (“C06” is displayed.) 9. Push [∧] [∨] to change functional data. (Cause “F00” to be displayed.) 10. Push [FUNC/DATA]. ( “0” is displayed.) 11. Push [STOP] and [∧] at the same time. (The display changes from “0” to “1”.) 12. Push [FUNC/DATA]. (“F01” is displayed, thereby inside data are prohibited from changing.) 13. Push [PRG/RESET]. (Program mode is canceled.) < Where mold height inverter is mounted > Remove the cover at the power supply portion, and you can see it below the center. ※ The digital display works only while the motor is turned on. Digital display Display various functional codes and data codes in times of program setting. Displays output frequency/output current during running and code of the cause of the abnormality by at the time of safeguard stop respectively. Program key (reset) Makes changeover between normalmode and program setting mode.Cancels the abnormal stop condition in times of safeguard function working. Function key (data key) Permits changeover between frequency display and output current display both during stop and running at the time of normal mode.Permits the read-out and write-in of varied functional codes and functional data at the time of program setting mode. Running key Not used. Set by TOYO: External signal (digital input) Stop key Not used. Set by TOYO: External signal (digital input) Used only when changeover is made between data protection and data change possible Up-down key Permits operation of frequency up and down. Permits change in functional codes and data setting values at the time of program setting mode. < Reference > When the mold height inverter is replaced by a new one because of something wrong with itself, change all the parameters shown in the following table. And push either [∧] or [∨] after canceling program mode, thus adjusting action frequency data to 60.0. Parameter F01 F02 F07 F08 F26 C05 Designation Initial value Frequency setting 4 Running/operation 2 Acceleration time 6.0 Deceleration time 6.0 Motor running sound 2 Multistage frequency 1 0.0 Value set by TOYO Unit 0 --- 1 --- 0.2 s 0.1 s 15 kHz 3.0 Hz 因篇幅问题不能全部显示,请点此查看更多更全内容