Product Information

DuPont Zytel HTN

high performance polyamide resin

™®

Zytel HTN51G35HSLR BK420

®

Zytel® HTN51G35HSLR BK420 is a 35% glass reinforced, heat stabilized, lubricated high performance polyamide resin with improved hydrolysis resistance.

Property

Identification Part Marking Code Part Marking CodeMechanical Stress at Break Strain at Break Tensile Modulus Flexural Modulus

Notched Charpy Impact Strength Unnotched Charpy Impact Strength

ISO 527ISO 527ISO 527ISO 178ISO 179/1eAISO 179/1eU

MPa (kpsi)

%MPa (kpsi)MPa (kpsi)kJ/mkJ/m2

2

Test MethodUnits

ValueDAM>PA6T/XT-GF35<>PPA-GF35<200 (29)2.311500 (1670)10500 (1520)

950

835190 (27.5)

2.011500 (1670)50%RHISO 11469SAE J1344

Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etcISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.

During molding, use proper protective equipment and adequate ventilation. Avoid exposure to fumes and limit the hold up time and temperature of the resin in the machine. Purge degraded resin carefully with HDPE.

The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2009

090324/090326

The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; thesedata may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you mayneed to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication

is to be considered as a license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. CAUTION: This product is not permitted to be sold for use in medical applications

involving any implantation in the human body or where contact with internal body fluids or tissues will equal or exceed 24 hours. For applications involvincontact of less than 24 hours, see “DuPont Medical Caution Statement\

plastics.dupont.com

1 / 2

Product Information

Zytel HTN51G35HSLR BK420

®

Property

Thermal

Deflection Temperature 0.45MPa 1.80MPa

Melting Temperature 10°C/min, First Heat CLTE, Parallel -40 - 23°C (-40 - 73°F) 23 - 55°C (73 - 130°F) 55 - 125°C (130 - 257°F) 165 - 200°C (329 - 392°F) CLTE, Normal -40 - 23°C (-40 - 73°F) 23 - 55°C (73 - 130°F) 55 - 125°C (130 - 257°F) 165 - 200°C (329 - 392°F)Electrical Surface Resistivity Volume ResistivityOther Density

Molding Shrinkage Normal, 2.0mm Parallel, 2.0mmProcessing

Melt Temperature Range Melt Temperature Optimum Mold Temperature Range Mold Temperature Optimum Drying Time, Dehumidified Dryer Drying Temperature

Processing Moisture Content

Test MethodUnits

ValueDAM50%RHISO 75-1/-2 °C (°F)

276 (529)262 (503)

ISO 11357-1/-3ISO 11359-1/-2

°C (°F)

300 (572)

E-4/C (E-4/F)

0.2 (0.11)0.2 (0.11)0.15 (0.08)0.15 (0.08)

ISO 11359-1/-2E-4/C (E-4/F)

0.55 (0.31)0.58 (0.32)0.62 (0.34)0.75 (0.42)

IEC 60093IEC 60093ISO 1183ISO 294-4

ohmohm mkg/m3 (g/cm3)

%

>1E15>1E131470 (1.47)

0.60.2

°C (°F) °C (°F) °C (°F) °C (°F)h °C (°F)%

320-330 (610-625)

325 (620)140-160 (280-320)

150 (300)6-8100 (210)<0.10

Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etcISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.

The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2009

090324/090326

The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as newknowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; thesedata may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you mayneed to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication

is to be considered as a license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. CAUTION: This product is not permitted to be sold for use in medical applications

involving any implantation in the human body or where contact with internal body fluids or tissues will equal or exceed 24 hours. For applications involvincontact of less than 24 hours, see “DuPont Medical Caution Statement\

plastics.dupont.com

2 / 2

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- efsc.cn 版权所有 赣ICP备2024042792号-1

违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务